RecalcLastBarAfter
Initializes the calculation after expiration of the timeout, set in seconds.
RecalcLastBarAfter is used for the slow markets in which new ticks come in infrequently. Normally, calculation of the studies is performed in events when the immediate tick has come to a chart.
When the tick has not come since the moment of the last calculation and during timeout (sec) a new calculation is being initialized.
When the tick has been received before timeout expiration, time counter is reset and countdown for RecalcLastBarAfter(Timeout) starts anew.
Usage
RecalcLastBarAfter(Timeout)
Where:
- Timeout - the number of seconds.
Example
if (LastBarOnChart_s = True) then begin
Print("Current time: ", FormatTime("HH:mm:ss", ELTimeToDateTime_s(CurrentTime_s)), ".");
RecalcLastBarAfter(5);
end;
Returns the following:
Current time: 13:29:10.
Current time: 13:29:15.
Current time: 13:29:20.
Current time: 13:29:25.
Current time: 13:29:30.
Current time: 13:29:35.
Current time: 13:29:40.
Also note that in this example the RecalcLastBarAfter statement is only active if the condition returns true, meaning that if the current bar isn't the LastBarOnChart, the RecalcLastBarAfter statement is not executed.